• Comprehensive Safety Protection
      Comprehensive Safety Protection
      Vision ensures system reliability with high-safety materials, multi-layer module protection, and stable control systems.
    • All-Temperature Monitoring
      All-Temperature Monitoring
      Real-time thermal monitoring with early warnings and preventive actions to avoid safety incidents.
    • Full Lifecycle Monitoring
      Full Lifecycle Monitoring
      Battery Management System (BMS) continuously tracks and reports battery status, enhancing overall system safety.
    • Integrated Power
      Integrated Power
      Compact structure, smaller footprint, easy installation to meet fast deployment needs.
    • Modular Design
      Modular Design
      Flexible expansion and maintenance, reducing system failure risks and improving O&M efficiency.
    • High Integration
      High Integration
      Combines power supply, monitoring, and cooling functions, simplifying system setup and enhancing overall reliability.
    • Intelligent
      Intelligent
      Supports remote monitoring and smart alerts for full lifecycle power system management.
    • Smart Management Module with Real-Time Monitoring
      Smart Management Module with Real-Time Monitoring
      Built-in BMS enables real-time battery status tracking and early fault prevention.
    • High Safety & Wide Temperature Adaptability
      High Safety & Wide Temperature Adaptability
      Stable performance under extreme conditions ensures equipment safety.
    • Reusable & Pollution-Free
      Reusable & Pollution-Free
      Eco-friendly design supports sustainability with recyclable materials.
    • Long Cycle Life
      Long Cycle Life
      Durable and reliable for frequent, long-term use, reducing replacement costs.
    • Safe & Reliable
      Safe & Reliable
      Long battery lifespan design with full-lifecycle diagnostics ensures stable operation
    • Smart & Efficient
      Smart & Efficient
      Real-time precise thermal control minimizes cell temperature differences, enhancing lifespan
    • Highly Integrated
      Highly Integrated
      Modular design adaptable to various scenarios
    • Easy Maintenance
      Easy Maintenance
      OTA updates, mobile app management, and cloud-edge collaboration
    Lithium BatteriesBattery SystemREVO Single-phase UPS Lithium ion Battery System
    REVO Single-phase UPS Lithium Battery System192V28AH
    REVO Single-phase UPS Lithium ion Battery System
    REVO Single-phase UPS Lithium ion Battery System
    REVO Single-phase UPS Lithium Battery System192V28AH
    REVO Single-phase UPS Lithium ion Battery System
    REVO Single-phase UPS Lithium ion Battery System

    REVO Single-phase UPS Lithium ion Battery System

    • Overview:
      The REVO Series is Vision Group's independently developed lithium battery product line designed for various UPS applications. The REVO Single-Phase SP Series features an integrated all-in-one design, offering compact size, easy maintenance, and flexible configuration options.

    • Application Scenarios:
      Data Centers
      Financial Institutions
      Rail Transit
      Power Backup for Off-Grid Areas

    Battery Quick Facts

    • Battery Type
      Battery Type
      Lithium Iron Phosphate (LFP)
    • Battery Discharge Efficiency
      Battery Discharge Efficiency
      >90%
    • Design Life
      Design Life
      15 years

    Key Features

    • Modular Design
      Supports both internal and external battery module installation for easy integration and optimized space usage.
    • Multi-Level Management Architecture
      Compatible with secondary and tertiary BMS systems, supports parallel operation of battery packs and flexible future expansion.
    • Multi-Protocol Communication Compatibility
      Supports CANBUS and MODBUS protocols for seamless integration with UPS hosts and supervisory systems.
    • High-Precision Monitoring
      Achieves voltage control accuracy within ±3mV and temperature management accuracy of ±1°C, ensuring stable system operation and cell consistency.

    Specification

    Model Capacity Cell Model Series-parallel connection Size(mm)Length*Width*Height Nominal Energy(kwh)
    SP12-9 12.8V9AH 12.8V9AH 4S1P 152*65*98 0.115
    SP12-100 12.8V100AH 3.2V100AH 4S1P 330*171*220 1.28
    SP12-200 12.8V200AH 3.2V100AH 4S2P 522*238*223 2.56
    SP36-50 38.4V50AH 3.2V50AH 12S1P 442*350*189 1.92
    SP36-100 38.4V100AH 3.2V100AH 12S1P 442*420*177 3.84
    SP36-200 38.4V200AH 3.2V100AH 12S2P 440*610*174 7.68
    SP48-50 48V50AH 3.2V50AH 15S1P 442*470*149 2.4
    SP48-100 48V100AH 3.2V100AH 15S1P 442*470*149 4.8
    SP51.2-50 51.2V50AH 3.2V50AH 16S1P 442*500*177 2.56
    SP51.2-100 51.2V100AH 3.2V100AH 16S1P 442*500*177 5.12
    SP51.2-200 51.2V200AH 3.2V100AH 16S2P 442*900*149 10.24
    SP72-50 72V50Ah 3.2V50AH 23S1P 440*650*174 3.68
    SP72-100 72V100Ah 3.2V100AH 23S1P 440*650*174 7.36
    SP192-9 192V9Ah 12.8V9AH 15S1P 442*800*149 1.72
    SP192-28 192V28Ah 3.2V6AH 60S5P 440*700*174 5.37
    Swipe Left or Right to View the Full Table

    FAQs

    • qWhat causes communication, voltage, or temperature self-check failure?
      a
      Possible Causes:
      1. Wiring issues
      2. Incorrect DIP switch settings
      3. Poor network cable connection

      Solutions:
      1. Check the network cable between CBMS and GBMS to rule out cable or hardware faults. If the LCD shows CBMS communication error, it’s often due to incorrect wiring between CBMS and GBMS.
      2. Verify the DIP switch settings for the parallel CBMS IP address, and ensure CAN/485 termination resistors are enabled on GBMS and the last battery cabinet’s CBMS.
      3. Inspect network cable connections between units for poor contact or loose connections.
    • qWhy can't the battery be charged?
      a
      Possible Causes:
      1. Charger or UPS mainboard failure
      2. Battery over-discharge triggered protection (voltage below cutoff level)
      3. BMS (Battery Management System) malfunction

      Solutions:
      1. Check if the charger output matches the battery specifications
      2. Try activating the battery using professional equipment
      3. Contact after-sales service to check the BMS or replace the battery

    NEED HELP FINDING THE BEST SOLUTION?

    Submit our form and we'll prioritize it.
    InformationInformation
    We collect your information (name, email, company) to respond to your inquiry and send marketing emails. You can unsubscribe or request deletion at any time. By submitting, you agree to our Privacy Policy.
    I agree to receive marketing emails and accept the Privacy Policy.